Personal information on this form will be used for the purposes of providing you information regarding events and event-related items. This information is collected under the authority of the Post-Secondary Learning Act that mandates the programs and services offered by The Banff Centre and will be protected by the provisions of the Alberta Freedom of Information and Protection of Privacy Act (FOIP).

Walter Phillips Gallery Facility Details

Structure

  • Constructed in 1976
  • Built originally as a contemporary art gallery
  • Average exhibitions per year: six
  • Average duration: two months
  • Receives circulating exhibitions
  • Loans to other institutions
  • Maintains a permanent collection

Gallery

  • Gallery: 321 sq.m. (1053' 4")
  • Locations: first floor Glyde Hall
  • Walls: white Gyproc on plywood
  • Floors: hardwood
  • Height of ceiling: 4.7 m (15' 5")

Floor Plan

Walter Phillips Gallery Floor Plan
View larger image

All measurements in metres. Walls are 3 metres high.
Lighting tracks are suspended from floating tracks and fall just below this height.
Note: There is an additional metre of open space above wall height which houses air duct work and other piping. This area is not recommended for use.

Access

  • Doors: leading from shipping/receiving to exhibition area:
  • Largest door: height 3.6 m width: 3 m
  • Separate shipping area
  • Loading platform is covered; truck can back in level to it
  • Height from ground: 9 m
  • Loading door: height: 2.4 m Width: 2.4 m
  • Crate storage area: 14.8 m
  • Person who packs / unpacks crates: Preparator

Environment

  • Windows in exhibition area: none
  • Air conditioning equipment
  • Humidifying equipment: spray type
  • Average year-round humidity: 45%
  • Fluctuation within 24 hours: 2%
    (Exterior relative humidity in winter may be extremely low in Banff, therefore we maintain gallery levels at 40% for most exhibits. Works entering the gallery in that time period have normally been acclimatized to a drier atmosphere and to subject them to standard 50% relative humidity would be an unacceptable fluctuation. In cases where works arrive in a controlled-atmosphere truck, the relative humidity may be increased at any time to meet prevalent conditions).
  • Average year-round temperature range in exhibition area: 20°C
  • Temperature fluctuation within 24 hours: 2°C
  • Same environmental control in exhibition and storage area
  • Heating: hot water
  • Fuel: gas
  • Heating system and air conditioning include air-filtering devices.
  • Smoking is not permitted in exhibition and preparation area.

Lighting

  • Lighting in exhibition area: incandescent
  • Lighting facilities: lightolier track system with various and movable fixtures, light meter.
  • Exhibition area light levels: maximum 150 lux (according to National Gallery standard)
  • Light may be maintained at different preferred levels in separate areas of the gallery.
  • Electrical outlets in exhibition areas: 8 3-prong
  • Power in exhibition area drawn from: wall, ceiling

Insurance

  • Art works are insured while in transit (within Canada) and while on the premises of the Banff Centre (all risks policy).
  • Policy includes fine arts floater rider (up to $50,000 per exhibition)
  • Condition reports kept on borrowed items in travelling exhibitions, incoming and out-going
  • Reports completed by: curator

Fire

  • Material of basic gallery structure: non-combustible wood and concrete.
  • Type of fire department: volunteer
  • Type of water supply: city
  • Supply of electrical service: 600 volts 3 phase
  • Maximum size of electrical service: 400 amp
  • Emergency system in case of power failure: none

Extinguishers

  • Sprinkler: other areas
  • Dry chemical: available in storage area
  • Heat sensor system is connected to local fire station
  • Walls and ceilings are fire resistant in exhibition area

Security

  • The gallery keeps hygrothermographic charts which staff check on a regular basis.
  • Mechanical maintenance: staff perform daily checks on thermostats, humidistats and other air control equipment and are on duty on a 24 hour basis to respond to any emergency.
  • While open, the gallery employs surveillance staff who oversee the exhibition area and assist the public.
  • While closed, the gallery is protected by a security system consisting of microwave motion detectors and door contact switches.
  • Security personnel carry out regular facility checks both outside and inside the gallery premises.

Publicity

Publicity measures: press releases, paid advertisements, invitations, handouts, media coverage, brochures, catalogues

Gallery Van

Interior Dimensions:

  • Height: 1.968 m (6'5 5")
  • Length: 4.826 m (15' 10")
  • Width: 2.336 m (7' 8")